Language:

2500kVA Power Distribution Transformer

Short Description:

China 2500kVA (2.5MVA) oil immersed power distribution transformer with high quality and good price....


Describe

Technical Tables

Drawing

2500kVA power distribution transformer is manufactured by WEIFAN GROUP Electric. WEIFAN GROUP is engaged in manufacturing, developing, marketing of HV/LV power distribution transformers for more than 20 years. As a professional transformer manufacturer in China, we can customize most types of power distribution transformers with different voltages and capacities, please feel free to contact us for a customized quotation. 

 

Technical Data of the 2500kVA Power Distribution Transformer:

Rated voltage: 10kV

Rated capacity: 2500kVA

Rated frequency: 50Hz/60Hz

Number of phases: 3 phases

Short circuit impedance: 6.61%

Connection group label: Dyn11

Cooling method: ONAN

 

Features of the 2500kVA Power Distribution Transformer:

1. The 2500kVA transformer has compact structure, low temperature rise and noise, and strong overload capacity. High-quality silicon-steel plates for lower loss.

2. The tank body adopts a corrugated oil tank fully sealed structure to prevent air and water from contacting the transformer, reduce oil aging, and extend the service life of the transformer; the elastic deformation of the corrugated sheet adjusts the volume change of the transformer oil thermal expansion and contraction.

3. The power distribution transformer is an outdoor structure with a high level of anti-pollution; there is no need to replace the transformer oil during the normal use period, and it is maintenance-free, ensuring the safe operation and reliability of the power grid.

4. The transformer is equipped with a pressure release safety protection device. When the transformer fails and the pressure is too high, it can be reliably and safely released through the pressure release valve to prevent the explosion. High-quality rubber sealing material for preventing the transformers from aging or leakage.

Capacity (kVA) Voltage Combination Vector group No-load loss (W) Load loss (W) (75°C) Impedance voltage (%)   No-load current (%)
HV Tapping range of HV LV
25 6 kV 6.6Kv 10.5kV 11kV   ±5%,±2×2.5%   0.38 kV 0.4 kV 0.415 kV 0.48 kV   Yyn0 Dyn5 Dyn11 100 600 4.0 1.7
50 130 870 1.6
63 150 1040 1.5
80 180 1250 1.4
100 200 1500 1.3
125 240 1800 1.2
160 280 2200 1.1
200 340 2600 1
250 400 3050 0.9
315 480 3650 0.9
400 570 4300 0.8
500 680 5100 0.8
630 810 6200 4.5 0.7
800 980 7500 0.6
1000 1160 10300 0.55
1250 1360 12000 0.5
1600 1640 14500 0.45
2000 1940 18500 5.5 0.4
2500 2300 20500 0.4